Chambers

Depending on the system you ordered, you may have one or more of the following chambers.

10 cm survey chamber

The 10 cm survey chamber (8100-102) includes the chamber, spares kit (part number 8100-621), replacement gasket kit (part number 8100- 622), and the 6000-09TC soil temperature probe.

Spares kit

Table 1‑1. The 10 cm chamber spares kit components.
Description Qty. LI-COR Part No.
10 cm Survey Chamber Spares Kit 1 8100-621
Cable Ties 10 218-08499
Bev-a-line Tubing (11'; 3.35 m) 1 222-01824
Thumb Nut 4 165-00140
10 cm Soil Collars 6 6581-157

Gasket kit

Table 1‑2. The 10 cm chamber gasket kit components.
Description Qty. LI-COR Part No.
10 cm Survey Chamber Gasket Kit 1 8100-622
Foam Seal Gaskets 20 6560-229
Soil Collar Gaskets 2 6581-065
Chamber Flange Gaskets 2 6581-066
Manifold Gaskets 2 6581-057
Chamber Gasket Trim (2.2'; 0.67 m) 1 226-07390
Loctite Adhesive 1 208-05786
10-32 x 1/2" screws 4 122-00014
4-40 x 3/8" screws 18 122-01578
8-32 x 1/2" screws 4 122-04328

Bellows kit

The bellows kit is an optional accessory that can be purchased individually.

Table 1‑3. The bellows kit components.
Description Qty. LI-COR Part No.
LI-8100A Bellows Kit (optional) 1 8100-623
Silicone Lubricant 1 210-01958-1
10-32 x 1/2" screws with o-ring 4 138-07470
Manifold Gasket 1 6581-057
Bellows, 3" I.D. x 4.25" O.D. 1 254-7219

20 cm survey chamber

The 20 cm survey chamber (8100-103) includes the chamber, spares kit (part number 8100-631), replacement gasket kit (part number 8100- 632), and the 6000-09TC soil temperature probe.

Spares kit

Table 1‑4. The 20 cm survey chamber spares kit components.
Description Qty. LI-COR Part No.
8100-103 Survey Chamber Spares Kit 1 8100-631
Cable Ties 10 218-08499
Bev-a-line Tubing (11'; 3.35 m) 1 222-01824
Thumb Nut 4 165-00140
20 cm Soil Collars 6 6581-044

Gasket kit

Table 1‑5. The 20 cm survey chamber gasket kit components.
Description Qty. LI-COR Part No.
20 cm Survey Chamber Gasket Kit 1 8100-632
Cap Nuts 4 163-02618
Foam Seal Gaskets 20 6581-107
Manifold Gaskets 2 6581-057
Soil Collar Gaskets 4 6581-108
Chamber Gasket Trim (6'; 1.8 m) 1 224-07606
Loctite Adhesive 1 208-05786
10-32 x 1/2" screws 4 122-00014
4-40 x 3/4" screws 2 158-07847
Flat washer, #10 4 167-00154

Bellows kit

The bellows kit is an optional accessory that can be purchased individually.

Table 1‑6. The bellows kit components.
Description Qty. LI-COR Part No.
LI-8100A Bellows Kit (optional) 1 8100-623
Silicone Lubricant 1 210-01958-1
10-32 x 1/2" screws with o-ring 4 138-07470
Manifold Gasket 1 6581-057
Bellows, 3" I.D. x 4.25" O.D. 1 254-7219

Long-term chambers

The 8100-104 and 8100-104C long-term chamber include the chamber, spares kit (part number 8100-613), and a replacement gasket kit (part number 8100-612).

Chamber spares kit

Table 1‑7. The long-term chamber spares kit components.
Description Qty. LI-COR Part No.
8100-104/C Long-Term Chamber Spares Kit 1 8100-613
Cable Ties 9 218-08499
Urethane Tubing (6'; 1.8 m) 1 222-00303
Thumb Nut 4 165-00140
20 cm Soil Collars 2 6581-044
Bumpers 4 191-08069
Cap Plugs 5 620-08297

Gasket kit

Table 1‑8. The long-term chamber gasket kit components.
Description Qty. LI-COR Part No.
8100-104/C Long-Term Chamber Gasket Kit 1 8100-612
Loctite Adhesive 1 208-05786
Collar Gasket 2 6581-060
Chamber Gasket Trim (6'; 1.8 m) 1 224-07606
6-32 x 3/8" screws 4 122-00009
4-40 x 3/8" screws 18 122-01578